开关寿命试验机是广东安规检测有限公司根据标准IEC60335-1第24.1.3节设计制作而成。
IEC60335标准要求:
24.1.3 The relevant standard for switches is IEC 61058-1. The number of cycles of operation declared for 7.1.4 of IEC 61058-1 shall be at least 10 000. If they have to be tested, they are tested in accordance with annex H.
NOTE 1 The declared number of operating cycles is only applicable for switches required for compliance with this standard.
If the switch operates a relay or contactor, the complete switching system is subjected to the test.
NOTE 2 Motor starting relays complying with IEC 60730-2-10 are not retested.
Annex H 17 Endurance
Compliance is checked on three separate appliances or switches.
For 17.2.4.4, the number of cycles of actuation declared according to 7.1.4 is 10 000 unless otherwise specified in subclause 24.1.3 of the relevant part 2 of IEC 60335.
Switches intended for operation under no load and which can be operated only with the aid of a tool are not subjected to the tests. This applies also for such switches operated by hand that are interlocked so that they cannot be operated under load. However, switches without this interlock are subjected to the test of 17.2.4.4 for 100 cycles of operation.
Subclauses 17.2.2 and 17.2.5.2 are not applicable. The ambient temperature during the test is that occurring in the appliance during the test of Clause 11 in IEC 60335-1, as specified in footnote b of Table 3.
At the end of the tests, the temperature rise of the terminals shall not have increased by more than 30 K above the temperature rise measured in clause 11 of IEC 60335-1.
产品规格参数:
1、7寸彩色触摸屏交互
2、信捷4轴PLC控制
3、雷塞步进电机驱动
4、支持跷跷板开关(又名船式开关)、琴键开关、旋钮开关共三个独立工位,单独测试,互不干涉
5、船式开关支持3档测试
6、琴键开关支持5键测试
7、旋钮开关支持任意角度设定测试,测试速度任意设置
8、任意工位测试完成报警,不影响其他工位测试
9、铝型材、A3烤漆钢板、不锈钢、氧化铝板复合结构